Instrumentation Cables for Industrial Applications
Instrumentation Cables
§ Insulation: HEPR/PVC , PVC/PVC , PE/PVC , XLPE/PVC
Manufactured with the following components/features:
§ Rated voltage: 300/300V , 300/500V , 450/750V , 0,6/1 kV
§ Bare or Tinned Copper Conductor: Flexible Stranded, Round Stranded, Solid Round
§ Cores twisted in: Pairs , Triads , Quads
§ Colour of insulation according to International Standards or on customer specification
§ Al / Polyester tape shield with tinned copper drain wire: on each Pair/Triad/Quad, Overall, on Each Pair/Triad/Quad & Overall
§ Bare or tinned copper braid shield: on each Pair/Triad/Quad, Overall, on Each Pair/Triad/Quad & Overall
§ Armours: Steel Braid / Steel Wires / Steel Tapes
§ Outer sheath: Colour according to International Standards or on customer specification
§ Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant
* Halogen free Instrumentation Cables
§ Insulation: MGT/HEPR/LSZH , MGT/EPR/LSZH , MGT/XLPE/LSZH
Manufactured with the following components/features:
§ Rated voltage: 300/300V , 300/500V , 450/750V 0,6/1 kV
§ Fire resistance according to: IEC 60331-21 // CEI EN 50200 or CEI EN 50362
§ Bare or Tinned Copper Conductor: Flexible Stranded, Round Stranded, Solid Round
§ Cores twisted in: Pairs , Triads , Quads
§ Colour of insulation according to International Standards or on customer specification
§ Al / Polyester tape shield with tinned copper drain wire: on each Pair/Triad/Quad, Overall, on Each Pair/Triad/Quad & Overall
§ Bare or tinned copper braid shield: on each Pair/Triad/Quad, Overall, on Each Pair/Triad/Quad & Overall
§ Armours: Steel Braid / Steel Wires / Steel Tapes
§ Outer sheath: Colour according to International Standards or on customer specification
§ Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant
Fire resistant/circuit integrity Instrumentation Cables
§ Insulation: HEPR/LSZH , EPR/LSZH , XLPE/LSZH
Manufactured with the following components/features:
§ Rated voltage: 300/300V , 300/500V , 450/750V , 0,6/1 kV
§ Bare or Tinned Copper Conductor: Flexible Stranded, Round Stranded, Solid Round
§ Cores twisted in: Pairs , Triads , Quads
§ Colour of insulation according to International Standards or on customer specification
§ Al / Polyester tape shield with tinned copper drain wire: on each Pair/Triad/Quad, Overall, on Each Pair/Triad/Quad & Overall
§ Bare or tinned copper braid shield: on each Pair/Triad/Quad, Overall, on Each Pair/Triad/Quad & Overall
§ Armours: Steel Braid / Steel Wires / Steel Tapes
§ Outer sheath: Colour according to International Standards or on customer specification
§ Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant
* Instrumentation Cables - Cables for low-temperature applications
§ Insulation: HEPR/PVC , PVC/PVC , EPR/LSZH , XLPE/PVC , XLPE/LSZH
Manufactured with the following components/features:
§ Rated voltage: 300/300V , 300/500V , 450/750V , 0,6/1 kV
§ Fire resistance according to: IEC 60331-21 // CEI EN 50200 or CEI EN 50362
§ Cores twisted in: Pairs , Triads , Quads
§ Colour of insulation according to International Standards or on customer specification
§ Al / Polyester tape shield with tinned copper drain wire: on each Pair/Triad/Quad, Overall, on Each Pair/Triad/Quad & Overall
§ Bare or tinned copper braid shield: on each Pair/Triad/Quad, Overall, on Each Pair/Triad/Quad & Overall
§ Colour of insulation according to International Standards or on customer specification
§ Armours: Steel Braid / Steel Wires / Steel Tapes
§ Outer sheath: Colour according to International Standards or on customer specification
§ Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant
§ PVC and LSZH sheath available in versions ARCTIC -40 °C or ARCTIC -60 °C
* Thermocouple Cables
§ Insulation: HEPR/PVC , PVC/PVC , XLPE/PVC , PE/PVC
Manufactured with the following components/features:
§ Rated voltage: 300/300V , 300/500V , 450/750V , 0,6/1 kV
§ Versions in compliance with International Standards : ANSI MC 96.1 , IEC 60584 A , NF-C-42-324, DIN 43710 , BS 4937 and BS 1843
§ Flexible stranded or solid round alloy conductor (cables for extension): Type E (+ NiCr / - CuNi) , Type J (+ Fe / - CuNi) , Type K (+ NiCr / - Ni) , Type N (+ NiCrSi / - NiSi) , Type T (+ Cu / - CuNi)
§ Flexible stranded or solid round alloy conductor (cables for compensation): Type B (+ Cu / - Cu) , Type R (+ Cu / - CuNi) , Type S (+ Cu / - CuNi) , Type W (+ NiCr / - Ni)
§ Colour of insulation according to International Standards or on customer specification
§ Cores twisted in: Pairs
§ Al / Polyester tape shield with tinned copper drain wire: on each Pair, Overall, on Each Pair & Overall
§ Bare or tinned copper braid shield: on each Pair, Overall, on Each Pair & Overall
§ Armours: Steel Braid / Steel Wires / Steel Tapes
§ Outer sheath: Colour according to International Standards or on customer specification
§ Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant
* Thermocouple Cables - Halogen free cables
§ Insulation: HEPR/LSZH , EPR/LSZH , XLPE/LSZH , PE/LSZH
Manufactured with the following components/features:
§ Rated voltage: 300/300V , 300/500V , 450/750V 0,6/1 kV
§ Versions in compliance with International Standards : ANSI MC 96.1 , IEC 60584 A , NF-C-42-324, DIN 43710 , BS 4937 and BS 1843
§ Flexible stranded or solid round alloy conductor (cables for extension): Type E (+ NiCr / - CuNi) , Type J (+ Fe / - CuNi) , Type K (+ NiCr / - Ni) , Type N (+ NiCrSi / - NiSi) , Type T (+ Cu / - CuNi)
§ Flexible stranded or solid round alloy conductor (cables for compensation): Type B (+ Cu / - Cu) , Type R (+ Cu / - CuNi) , Type S (+ Cu / - CuNi) , Type W (+ NiCr / - Ni)
§ Colour of insulation according to International Standards or on customer specification
§ Cores twisted in: Pairs
§ Al / Polyester tape shield with tinned copper drain wire: on each Pair, Overall, on Each Pair & Overall
§ Bare or tinned copper braid shield: on each Pair, Overall, on Each Pair & Overall
§ Armours: Steel Braid / Steel Wires / Steel Tapes
§ Outer sheath: Colour according to International Standards or on customer specification
§ Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant
* Thermocouple Cables - Fire resistant/circuit integrity cables
§ Insulation: MGT/HEPR/LSZH , MGT/EPR/LSZH , MGT/XLPE/LSZH , MGT/PE/LSZH
Manufactured with the following components/features:
§ Rated voltage: 300/300V , 300/500V , 450/750V 0,6/1 kV
§ Fire resistance according to: IEC 60331-21 // CEI EN 50200 or CEI EN 50362
§ Versions in compliance with International Standards : ANSI MC 96.1 , IEC 60584 A , NF-C-42-324, DIN 43710 , BS 4937 and BS 1843
§ Flexible stranded or solid round alloy conductor (cables for extension): Type E (+ NiCr / - CuNi) , Type J (+ Fe / - CuNi) , Type K (+ NiCr / - Ni) , Type N (+ NiCrSi / - NiSi) , Type T (+ Cu / - CuNi)
§ Flexible stranded or solid round alloy conductor (cables for compensation): Type B (+ Cu / - Cu) , Type R (+ Cu / - CuNi) , Type S (+ Cu / - CuNi) , Type W (+ NiCr / - Ni)
§ Colour of insulation according to International Standards or on customer specification
§ Cores twisted in: Pairs
§ Al / Polyester tape shield with tinned copper drain wire: on each Pair, Overall, on Each Pair & Overall
§ Bare or tinned copper braid shield: on each Pair, Overall, on Each Pair & Overall
§ Armours: Steel Braid / Steel Wires / Steel Tapes
§ Outer sheath: Colour according to International Standards or on customer specification
§ Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant
* Thermocouple Cables - Cables for low-temperature applications
§ Insulation: HEPR/PVC, PVC/PVC, EPR/LSZH, XLPE/PVC, XLPE/LSZH
Manufactured with the following components/features:
§ Rated voltage: 300/300V , 300/500V , 450/750V , 0,6/1 kV
§ Fire resistance according to: IEC 60331-21 // CEI EN 50200 or CEI EN 50362
§ Versions in compliance with International Standards : ANSI MC 96.1 , IEC 60584 A , NF-C-42-324, DIN 43710 , BS 4937 and BS 1843
§ Flexible stranded or solid round alloy conductor (cables for extension): Type E (+ NiCr / - CuNi) , Type J (+ Fe / - CuNi) , Type K (+ NiCr / - Ni) , Type N (+ NiCrSi / - NiSi) , Type T (+ Cu / - CuNi)
§ Flexible stranded or solid round alloy conductor (cables for compensation): Type B (+ Cu / - Cu) , Type R (+ Cu / - CuNi) , Type S (+ Cu / - CuNi) , Type W (+ NiCr / - Ni)
§ Colour of insulation according to International Standards or on customer specification
§ Cores twisted in: Pairs
§ Al / Polyester tape shield with tinned copper drain wire: on each Pair, Overall, on Each Pair & Overall
§ Bare or tinned copper braid shield: on each Pair, Overall, on Each Pair & Overall
§ Armours: Steel Braid / Steel Wires / Steel Tapes
§ Outer sheath: Colour according to International Standards or on customer specification
§ Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant