Control Cables

§  Insulation: EPDM/EPDM , HEPR/PVC , PVC/PVC ,  XLPE/PVC

Manufactured with the following components/features:

§  Rated voltage: 300/300V , 300/500V , 450/750V 0,6/1 kV

§  Bare or Tinned Copper Conductor or Aluminum Conductor: Flexible Stranded, Round Stranded, Solid Round

§  Bare or Tinned Copper Concentric Conductor: Braid , Wires

§  Colour of insulation according to International Standards or on customer specification

§  Shields: Al / Polyester tape with tinned copper drain wire / Bare or Tinned Copper Braid / Copper Wires / Copper Tapes

§  Armours: Steel Braid / Steel Wires / Steel Tapes

§  Outer sheath: Colour according to International Standards or on customer specification

§  Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant

 

* Halogen free cables - CONTROL CABLES

§  Insulation: HEPR/LSZH , EPR/LSZH , XLPE/LSZH

Manufactured with the following components/features:

§  Rated voltage: 300/300V , 300/500V , 450/750V 0,6/1 kV

§  Bare or Tinned Copper Conductor or Aluminum Conductor: Flexible Stranded, Round Stranded, Solid Round

§  Bare or Tinned Copper Concentric Conductor: Braid , Wires

§  Colour of insulation according to International Standards or on customer specification

§  Shields: Al / Polyester tape with tinned copper drain wire / Bare or Tinned Copper Braid / Copper Wires / Copper Tapes

§  Armours: Steel Braid / Steel Wires / Steel Tapes

§  Outer sheath: Colour according to International Standards or on customer specification

§  Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant

 

* Fire resistant/circuit integrity cables  - CONTROL CABLES

§  Insulation: MGT/HEPR/LSZH , MGT/EPR/LSZH , MGT/XLPE/LSZH

Manufactured with the following components/features:

§  Rated voltage: 300/300V , 300/500V , 450/750V 0,6/1 kV

§  Fire resistance according to:  IEC 60331-21 // CEI EN 50200 or CEI EN 50362

§  Bare or Tinned Copper Conductor or Aluminum Conductor: Flexible Stranded, Round Stranded, Solid Round

§  Bare or Tinned Copper Concentric Conductor: Braid , Wires

§  Colour of insulation according to International Standards or on customer specification

§  Shields: Al / Polyester tape with tinned copper drain wire / Bare or Tinned Copper Braid / Copper Wires / Copper Tapes

§  Armours: Steel Braid / Steel Wires / Steel Tapes

§  Outer sheath: Colour according to International Standards or on customer specification

§  Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant

 

* Cables for low-temperature applications - CONTROL CABLES

§  Insulation: EPDM/EPDM ,  HEPR/PVC , PVC/PVC ,  EPR/LSZH , XLPE/PVC ,  XLPE/LSZH

Manufactured with the following components/features:

§  Rated voltage: 300/300V , 300/500V , 450/750V ,  0,6/1 kV

§  Fire resistance according to:  IEC 60331-21 // CEI EN 50200 or CEI EN 50362

§  Bare or Tinned Copper Conductor or Aluminum Conductor: Flexible Stranded, Round Stranded, Solid Round

§  Bare or Tinned Copper Concentric Conductor: Braid , Wires

§  Colour of insulation according to International Standards or on customer specification

§  Shields: Al / Polyester tape with tinned copper drain wire / Bare or Tinned Copper Braid / Copper Wires / Copper Tapes

§  Armours: Steel Braid / Steel Wires / Steel Tapes

§  Outer sheath: Colour according to International Standards or on customer specification

§  Oil Resistant / Hydrocarbon Resistant / Chemical Resistant / UV resistant /Thermite Resistant

§  PVC and LSZH sheath available in versions ARCTIC -40 °C or ARCTIC -60 °C